XenServer 6.2 does not show nvidia kernel module after installing nVIDIA vGPU Drivers Dell R720

While Trying to setup Dell R720 with NVIDIA Grid K2  for XenServer 6.2 SP1
It may happen that after you install the nvidia driver and reboot the server , the module for nvidia is not recognized .
To verify the install after reboot you may run the following command
 lsmod | grep nvidia

If it does not find any module then we may have to disable one setting in System BIOS for Dell R720 server.

This is the setting you need to disable. (Memory Mapped I/O above 4GB)

You can find it Under > System BIOS > Integrated Devices >



After the server come back online , you can run the following command to verify the module was loaded fine

lsmod | grep nvidia

The output should be something like

nvidia               9626462  26
i2c_core               20294  1 nvidia


Verify that the NVIDIA kernel driver can successfully communicate with the GRID physical GPUs in your system by running the nvidia-smi command.

The output should look like:


+------------------------------------------------------+
| NVIDIA-SMI 331.30     Driver Version: 331.30         |
|-------------------------------+----------------------+----------------------+
| GPU  Name        Persistence-M| Bus-Id        Disp.A | Volatile Uncorr. ECC |
| Fan  Temp  Perf  Pwr:Usage/Cap|         Memory-Usage | GPU-Util  Compute M. |
|===============================+======================+======================|
|   0  GRID K2             On   | 0000:06:00.0     Off |                  Off |
| N/A   36C    P8    27W / 117W |     10MiB /  4095MiB |      0%      Default |
+-------------------------------+----------------------+----------------------+
|   1  GRID K2             On   | 0000:07:00.0     Off |                  Off |
| N/A   33C    P8    27W / 117W |     10MiB /  4095MiB |      0%      Default |
+-------------------------------+----------------------+----------------------+
|   2  GRID K2             On   | 0000:44:00.0     Off |                  Off |
| N/A   37C    P8    28W / 117W |     10MiB /  4095MiB |      0%      Default |
+-------------------------------+----------------------+----------------------+
|   3  GRID K2             On   | 0000:45:00.0     Off |                  Off |
| N/A   35C    P8    28W / 117W |     10MiB /  4095MiB |      0%      Default |
+-------------------------------+----------------------+----------------------+

+-----------------------------------------------------------------------------+
| Compute processes:                                               GPU Memory |
|  GPU       PID  Process name                                     Usage      |
|=============================================================================|
|  No running compute processes found                                         |


Hope This helps.


Comments

Popular posts from this blog

Group Policy Object did not apply because it failed with error code '0x80070534 No mapping between account names and security IDs was done

One of our servers was losing the Local Admin settings as we control them using GPO (restricted Groups) We were receiving the following event on this particular server : Event ID 4098 Application Event Log The computer 'Administrators (built-in)' preference item in the 'Servers Local Admins {odjd9DBD-22AF-48EA-ADF5-F42ADE4182hst}' Group Policy Object did not apply because it failed with error code '0x80070534 No mapping between account names and security IDs was done.' This error was suppressed. To fix the issue we deleted all the folders from the following location and rebooted the server C:\ProgramData\Microsoft\Group Policy\History Hope this helps.

iDRAC 7 Shows no Signal in Virtual Console Preview

Recently i logged on to iDRAC for one of our Dell R720 servers,however somehow the console redirection did not work at all. I kept on seeing No Signal on the Virtual console Preview. I tried Rebooting the server but that did not help. Finally i clicked on Reset iDRAC and this did the trick. It may take around 2 -5 minutes before you can access iDRAC page again. I had to power on the server through iDRAC before anything showed up on console. Hope this Helps.

Citrix XenApp 6.5 Discovery fails Event 3989

Citrix XenApp 6.5 Service account password change caused console discovery to fail and we saw event ID 3989 in System Event logs "Citrix XenApp failed to connect to the Data Store. ODBC error while connecting to the database: 28000 -> [Microsoft][ODBC SQL Server Driver][SQL Server]Login failed. The login is from an untrusted domain and cannot be used with Windows authentication." After changing the service account password needed to run the following command on the delivery controllers. DSMAINT CONFIG /user:abc\ABCSVCCitrix /pwd:nP@ssword /dsn:"C:\Program Files (x86)\Citrix\Independent Management Architecture\mf20.dsn" Restart IMA service You should now be able to run the discovery successfully Hope this helps